The r value depends on the type of insulation its thickness and its density.
													
																	Ceiling insulation r value recommendation. 
								
	
		
	
																	For example if you have a type of insulation that has an r value of r 5 per inch of thickness you will need a depth of 6 inches of this insulation installed in your attic to reach r 30 if you live in zones 2 or 3. 
																	Where you live different climates require different insulation r values. 
																	Insulate the garage s ceiling by using the recommended r value for your area as advised by the department of energy s oak ridge laboratory. 
																	These r values are a sum meaning this should be the total r value once you add up the entire depth of insulation. 
															
													
								
	
		
	
																	Typical recommendations for exterior walls are r 13 to r 23 while r 30 r 38 and r 49 are common for ceilings and attic spaces. 
																	When insulating ceilings in warmer climates or when using higher density materials as little as 8 inches of thickness may suffice. 
																	Insulation level are specified by r value. 
																	Higher r value numbers mean that the insulating material resists the cold or heat from the outside better. 
															
													
								
	
		
	
																	Basics of faced fiberglass insulation from r 13 to r 19 r value is a standard unit of measurement for determining among many things how effective your insulation will be. 
																	See the department of energy s doe ranges for recommended levels of insulation below. 
																	The amount of insulation recommended for your home will vary depending on a number of factors. 
																	The table below shows what levels of insulation are cost effective for different climates and locations in the home. 
															
													
								
	
		
	
																	When calculating the r value of a multilayered installation add the r values of the individual layers. 
																	According to the doe 8 inches of high density batt insulation will provide around an r 30. 
																	Foam in place insulation can be injected into walls to reduce air leakage and improve r value. 
																	R value is a measure of insulation s ability to resist heat traveling through it. 
															
													
								
	
		
	
																	Foam insulation r values range from r 4 to r 6 5 per inch of thickness 2 54 cm which is up to 2 times greater than most other insulating materials of the same thickness. 
																	The r refers to absolute thermal resistance. 
																	You will need a higher r value of insulation if you live in the northeast than if you live in southern california. 
																	The higher the r value the better the thermal performance of the insulation. 
															
													
								
	
		
	
																	The r value of some insulations also depends on temperature aging and moisture accumulation. 
																	Exterior walls if your exterior walls are constructed from 2 by 4 inch studs the most insulation that can go into the wall while retaining its r value is r 13 or r 15 as these are both made to fit a cavity 3 1 2 inches deep.